After-sales Service: | 1 Year |
---|---|
Condition: | New |
Speed: | Super High Speed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Since 2014,One-stop Professional Solution for
Semiconductor Front-end and IC TO Package Equipments Line
360-8 inch wafer bonding machine technical specifications | |||
Solid crystal workbench (linear module) | Optics System | ||
Workbench stroke | 450x220mm | Camera | |
Resolution | 1μm | Optics Magnifier | 0.7 times ~ 4.5 times |
Epistar Workbench (Linear Module) | Cycle Time | 200MS/EA | |
XY stroke | 8"*8" | Die bond cycle | Less than 250 milliseconds |
Resolution | 1μm | Production capacity | Greater than 12k |
Accuracy of wafer placement | Loading and unloading module | Manual loading and unloading | |
Stick position x-y | ±2mil | ||
Rotation accuracy | ±3° | ||
Dispensing module | Equipment Require | ||
Use swing arm dispensing + heating system | Voltage | AC220V/50HZ | |
The dispensing needle group can be interchanged with single needle or multiple needles | Air Source | At least 6BAR | |
Vacuum Source | 700mmHG | ||
Power Consumpion | 3000w | ||
PR System | Dimensions And Weight | ||
Method | 256 grey levels | Weight | 450kg |
Detection | Ink/chipping/cracked die | Size(DxWxH) | 1200*900*1500mm |
Monitor | 17" LCD | ||
Monitor Resolution | 1024*768 | Missing Die | Vacuum Sensor |
380-12 inch wafer bonding machine technical specifications | |||
Solid crystal workbench (linear module) | Optics System | ||
Workbench stroke | 100x300mm | Camera | |
Resolution | 1μm | Optics Magnifier | 0.7 times ~ 4.5 times |
Epistar Workbench (Linear Module) | Cycle Time | 200MS/EA | |
XY stroke | 12"*12" | The die bonding cycle is less than 250 milliseconds, and the production capacity is greater than 12k; |
|
Resolution | 1μm | ||
Accuracy of wafer placement | Loading and unloading module | ||
Stick position x-y | ±2mil | Automatic feeding method using vacuum suction cup Unloading using the material box container type receiving material Use pneumatic pressure plate type clamp, the width of the bracket can be adjusted in the range of 25~90mm |
|
Rotation accuracy | ±3° | ||
Dispensing module | Equipment Require | ||
Use swing arm dispensing + heating system The dispensing needle group can be interchanged with single needle or multiple needles |
Voltage | AC220V/50HZ | |
Air Source | At least 6BAR | ||
Vacuum Source | 700mmHG(Vacuum pump) | ||
Power Consumpion | 3000w | ||
PR System | Dimensions And Weight | ||
Method | 256 grey levels | Weight | 450kg |
Detection | ink /chipping/cracked die | Size(DxWxH) | 1200*1200*1500mm |
Monitor | 17" LCD | ||
Monitor Resolution | 1024*768 |
Bonding arm | |
Bonding arm | 90 degree |
Motor | AC servo moto |
Wafer work stage | |
Stroke | 6"*6" |
resolution | 0.2 mil (5μm) |
Lead frame wore stage | |
Lead frame number | 1PC |
Stroke | 10"*6" |
Resolution | 0.2 mil (5μm) |
Die and wafer | |
Die dimension | 5mil*5mil~100mil*100mil |
Wafer dimension6 | 6 |
:±3° | |
:±1.5mil | |
25g~35g | |
Ejector system | |
Sync with the part | |
Can adjust the height | |
Epoxy picking system | |
Epoxy picking arm | Rotary type |
moto | AC servo moto |