Digital Metal Coating Electrolytic Thickness Gauge Meter

Warranty: 1 Year
Condition: New
Usage: Width Measuring Instruments
Alloy Coating Measurement: Pd-Sn,Cu-Zn,Zn-Ni,Ni-P,etc.
Effective Measurement of Thickness Range: 0.03~300μm
Measurement Accuracy: ±8%
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Diamond Member Since 2017

Suppliers with verified business licenses

Basic Info.

Model NO.
MD-DJ1
Reproducibility
<3%
Electrolytic Current Accuracy
±0.5%
Power Supply
AC220±10%V;0.7A;50Hz/60Hz±0.5Hz
Selective Purchasing
AC115V,100V,120V,230V,240V
Transport Package
Standard Export Case Packing
Specification
350× 260× 160mm
Trademark
Minder
Origin
Guangdong, China (Mainland)
Production Capacity
200sets/Month

Product Description

Product Show
Digital Metal Coating Electrolytic Thickness Gauge Meter



 

Product Description

Electrolytic Thickness Gauge is a metal plating electrolytic thickness gauge combined with the most advanced technology at home and abroad, with advanced structure, stable and reliable performance, complete features. Using this instrument can guarantee the product quality of the user and prevent the waste of raw materials energy. The use of this instrument can also help users find the best electroplating process for different requirements. It is the preferred instrument for finished products and electroplating factories.

 

Main functions and features

1,Chinese and English interface switching, LCD display, high display quality, digital interface, small size, light weight, low power consumption, etc.

2,The thermal printer is permanently used without changing the ribbon. Micro-printing interface prints Chinese and English test report, print coating type, thickness, tester, date, internal clock perpetual calendar, no need to set each time

3,Automatic pause measurement prompts replacement of electrolyte. To reduce measurement error.

4,Automatically calculate the average. Below 10 microns is three decimal places, precision 1/1000

5,Measurable multilayer plating, such as: Cr/Ni/Cu/Plastic, reports can print out the results at once, without disassembly printing (exclusive).

6,Adjust the terminal potential difference to suit the potential between the coating and the substrate

7,By measuring more than 70 kinds of metal plating substrate combinations, the electrolytic thickness gauge can measure plating on planes and surfaces, measuring small parts, wires, and linear parts.

8,Removal coating speed adjustable from 0.3-40 μm/minute.

9,The vacuum extruded air pump can be stirred by cycle, according to the coating, we can adjust the stirring intensity and gas volume to achieve the best dissolution state.

10,Electrolytic cup material is corrosion-resistant alloy stainless steel, not easy to corrode aging.

11,Adjustable constant current to achieve the best value of electrolytic efficiency.

 

Technical Parameters

Single-layer measurement species

Nickel(0); Chromium(1) ;Copper(2); Zinc(3); Cadmium(4); Tin(5); Lead(6); Silver(7); Gold(8); Copper/Zn(9) ; Chrome/T(10); Nickel/Fe(11) etc, other coatings can be customized. Note: A, Nickel (0) is used for nickel plating on copper; Nickel/Fe (11) is used for nickel plating on iron, aluminum, plastics, and ceramics. It is measured at slow speed when measuring chemical nickel. B,Chromium (1) for decorative chromium and hexavalent and tetravalent chromium (0.001-20 μm); Chromium/T (10) for thick chromium above 20 μm. C,Copper (2) is used for copper plating on iron, aluminum, plastics, ceramics, etc. Copper/Zn (9) is used for copper plating on zinc and zinc alloys.

Alloy coating measurement

Pd-Sn,Cu-Zn,Zn-Ni,Ni-P,etc.

Multilayer plating measurement

Multilayer plating on ceramics, plastic, iron, aluminum and copper substrates

Effective measurement of thickness range

0.03~300μm

Measurement accuracy

±8%

Reproducibility

<3%

Electrolytic current accuracy

±0.5%

Measuring surface diameter

Φ3.0mm;Φ2.5mm;Φ1.7mm;

Power supply

A C220±10%V;0.7A;50HZ/60HZ±0.5HZ;good and reliable grounding is required.

selective purchasing

AC115V,100V,120V,230V,240V

Use environment

Temperature: +10~+40ºC; Relative humidity: not more than 85%; no strong corrosive gases and strong magnetic fields are required.

Weight of host

6Kg

Dimension

350×260×160mm(Length × width × height)

 

Notice when ordering

1,The customer should confirm the substrate (this instrument is not restricted by any substrate).

2,Users should confirm the basal body and coating ,and the type and order of the coating.

3,According to customer needs choose the appropriate model.

4,The user should confirm the size of the test work piece.

5,Users must choose electrolytic thickness meter range: plastic, ceramic and other non-metallic coating thickness measurement, tin, nickel, silver metal plating thickness measurement, thickness measurement of multilayer plating, small workpiece coating thickness measurement, coating potential difference Analysis, dissolution analysis.

Note:This product can measure nickel, chromium, copper, zinc, cadmium, tin, silver, gold, zinc alloy plating, chemical nickel, etc. and many kinds of plating. This product cannot measure copper plating on multilayer nickel and copper, and it is impossible to analyze their potential difference (can be connected to a computer, analysis of measurement curve and measurement report).

 

If you need more further details about our products,  please feel free to contact us .

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now