Basic Info.

Model NO.
MD-5V30A

Product Description

The equipment accuracy is 0.05%, and the data recording time is 1 second/time,
The fastest is 0.1 second/time, and the stability is high.
^The software has powerful functions and friendly man-machine interface.
^Four-wire system test interface to ensure high measurement accuracy.
^Modular design concept, easy to maintain.
Device model MDS-5V30A Single channel
Output power
150W communication method TCP/IP (Network port)
Discharge voltage 5V-0.8V Charging voltage DC0-5V data record 100mS~65535 S
Recharging current 5Vseries:0.02A~30A Discharge current 5Vseries:0.02A~30A
Current accuracy ±(0.05%RD+0.05%FS) Voltage accuracy ±(0.05%RD+0.05%FS)
Voltage resolution When the 1mV device detects or sets the voltage The smallest unit used
Electric current resolution 1mA device is detecting or setting voltage The smallest unit used
Charging mode Constant current charging Constant voltage charging
Discharge mode Constant current discharge  Constant power discharge
Charging cut-off
condition
Voltage,current,time, capacity,temperature Discharge cut-off
condition
Voltage,current,time,capacity,temperature
5V30A battery testing equipment, mainly used for: soft pack polymer battery Cylindrical battery
The star product in the 3C tester, with
High response, high precision, high sampling and other performance characteristics, simple structure and modular
A single test device is designed for 8 channels, each
Channel independent programming, and supports 254 working steps at most, and the time error of the working steps does not exceed 50ms.
Test mode support:
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging.
Constant current discharge, constant power discharge.
  Input power AC220±10%/50Hz (Cabinet power supply mode: three-phase five-wire)
  Main temperature According to a particular apparatus 1 channel per channel optional
  input resistance 10MQ
  Current response time Current rise time ≤50mS Power accuracy ±(0.05%RD+0.05%FS)
  Number of steps in a single cycle 100step,With nested loop function
  Circuit configuration Modular structure design, easy replacement and maintenance
  VCELL,TCELL Optional auxiliary temperature, auxiliary voltage, single module 8 channels, can be arbitrarily mapped to each main channel Temperature range: -40~140° (Voltage range: 0~5V/0~20V)
performance index parameter  
Input power AC220V ±10%/50Hz  

Voltage
Measuring range 0.75~5V  
  Output range 10mV~5V  
  Precision ±0.1%*FSR  
  Output accuracy ±0.1%*FSR  

Current
Measuring range 0~30A  
  Output range 50mA~30A  
  Measurement accuracy ±0.1%*FSR  
  Output accuracy ±0.1%*FSR  

Power
Measuring range 0~1500W  
  Output range 0~1500W  
  Measurement accuracy ±0.2%*FSR  
  Output accuracy ±0.2%*FSR  

Data probability
Sampling rate 1HZ:1 samples/sec  
  Recording rate 1HZ:1 point/sec  
  Recording conditions T I V temp  
Full-scale current response time ≤30ms  
Time resolution 1s  
input resistance ≥1MOhm  
Support charge and discharge type Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant load discharging, constant power discharging, support channel paralleling  
Number of test commands 399 commands can be set, 65535 loops can be set, 5 levels of nested loops are supported  
communication method Ethernet,100Mbps  
safety protection hardware Add anti-reverse connection module to prevent battery reverse connection  
  software 1 Power-down data protection
2Support the setting of protection conditions: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, energy upper limit, voltage change rate, delay protection, temperature upper limit, temperature lower limit
 
Calibration frequency ≥1year  