After-sales Service: | 1 Year |
---|---|
Demoulding: | Automatic |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Manufacturer | Minder-hightech | Minder-hightech | Minder-hightech | Minder-hightech |
Model | MD-G25A | MD-G25D | MD-G31 | MD-G33 |
Exposure type | One side | One side | Double side alignment and double side exposure | |
Exposure head NO. | 1 Exposure head | 1 Exposure head | 2 Exposure head | 2 Exposure head |
Cooling method | Air cooling | Air cooling | Air cooling | Air cooling |
Type of light source | Mercury lamp source | Ultraviolet light source | Mercury lamp source | Ultraviolet light source |
Exposure area | ≤∅100mm | Φ100mm | ≤∅120mm | ≥∅115mm |
Exposure mode | Contact exposure | micro-force paralleling technology | micro-force paralleling technology | micro-force paralleling technology |
Light source | mercury | mercury | UV-LED | UV-LED |
Exposure unevenness | ∅100mm<±4% | ≤±3% | ∅100mm≤±6% | ≤±3%Exposureintensity≥20mw/cm2 (365nm,404nm,435nmCombined UV) |
Substrate thickness | 1-5mm | ≤5 mm | 0.1-1mm | ≤5 mm |
Exposure resolution | 3μm | 1 μm | 1 μm | 1 μm |
Alignment accuracy | ±0.5μm | 1 μm | Positive:1 μm / On the other side:3-5μm | 1 μm |
Lighting range | ∅115mm | ∅117mm | ∅120mm | Front and back ≥ ∅115mm |
Camera system | Binocular separation system | dual-field CCD system | dual-field CCD system | dual-field CCD system |
Microscope system | 50-375 continuous zoom | 91x ~ 570X continuous zoom (objective lens 1.6x ~ 10x continuous zoom), the adjustable range of double objective lens distance is 50mm ~ 120mm | 0.7-4.5 continuous zoom | 60x, 120x continuous zoom (objective magnification 2x, 4x two), double objective adjustable distance 25mm-70mm |