After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Type: | Batteries Monomer Tester |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
model | MDSC-S11-128-10A | MHSC-S12-512-3A |
Device channel number | The whole machine has a total of 128 channels | The whole machine has a total of 512 channels |
Dimensions | 950mm wide × 580mm deep × 1900mm high | Length 1684MM, width 756MM, height 1840MM, chassis width 500MM |
Chassis color | Bright gray (customizable) | Standard blue and black (customizable) |
Fixture form | Flat head fixture | 65 blue and white buckle |
Fixture spacing | 50mm-180mm | 85CM |
Support battery specifications | Cylindrical battery | Polymer battery |
Power supply | Three-phase five-wire system AC380V±10%, 50HZ | |
Working power consumption | ≤8KW | |
working environment | Temperature 0~40ºC, relative humidity≤80% | |
Cooling method | Natural intake, upward exhaust |
model | MDSC-S11-128/10A | MDSC-S12-512-3A |
Voltage measurement range | 0~5V | |
Battery voltage range | Charge 0~4.5V; Discharge 4.5~2V | |
Constant voltage range | 2.5~4.5V | |
Voltage accuracy | ±(1‰ reading+1‰ full scale) | ±(0.5‰ reading+0.5‰ full scale) |
Voltage resolution | 1mV | |
Voltage stability | ≤1‰ | ≤0.5‰ |
Current range | Charge 100mA~10A; Discharge 100mA~10A | Charge 10mA~10A; Discharge 10mA~10A |
Current accuracy | ±(1‰ reading+1‰ full scale) | ±(0.5‰ reading+0.5‰ full scale) |
Current resolution | 10mA | 1mA |
Stable current | ≤1‰ | ≤0.5‰ |
model | MDSC-S11-128-10A | MHSC-S12-512-3A |
way to control | The software is installed on the computer to connect to the equipment, and the whole cabinet is controlled | |
communication method | Serial port, baud rate 57600 | |
Process settings | Up to 32 steps and 256 cycles can be set | |
Charging mode | Constant current, constant voltage, constant current and constant voltage | |
Charging cut-off condition | Voltage, current, time, capacity | |
Discharge mode | Constant current | |
Discharge cut-off condition | Voltage, time, capacity | |
Protective function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery | |
time limit | Arbitrarily set within 0~30000 minutes, the time unit is min | |
Time accuracy | ≤±1‰ | |
Sampling inspection cycle | ≤4s | |
Minimum data recording frequency | ≤5s | |
Battery sorting | Sort by (capacity, time, open circuit voltage, discharge platform, etc.) | |
data processing | Can record voltage, current, time, capacity and other data, automatically calculate constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data, provide data graphs and cycle diagrams; can output generated text, EXCEL, WORD Or MDB database format file |