Type: Finished Batteries Tester
Test Region: Current
Application: Lithium-ion Battery
Customized: Non-Customized
Transport Package: Wooden Case
Specification: 980*600*1820mm
Diamond Member Since 2017

Suppliers with verified business licenses

Basic Info.

Model NO.
MD-70-05-10
Trademark
Minderhightech
Origin
Guangzhou-Guangdong
Production Capacity
1000sets/Month

Product Description

Battery pack charging & discharging test machine(1400W)

Voltage: 70V
Charging: 5A
Discharge: 10A


12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell

 

Basic performance:

♦Charging function: with constant current and constant voltage charging function
♦Discharge function: with constant current discharge function
♦Charge and discharge interface: fully meet the requirements of the same port and separate port for charging and discharging the battery pack, that is, 2 wires (P+ P-) and 3 wires (P+ P- C-), and can age the positive electrode to protect the negative plate from discharging Protection type power tool battery (CH+ P+ P-)

♦Check voltage protection: by charging and discharging the battery, can check whether the battery's charge protection and discharge protection work.
♦Record the charge and discharge capacity: charge and discharge the battery, and record the charge and discharge capacity of the battery.

♦Safety protection: anti-reverse connection protection function; voltage upper and lower limit setting protection; safe discharge current protection.

♦Serial port connection mode: If the instrument is single or less than 3, it can be connected to the PC through the serial port, which can reduce the complexity of using the instrument.

♦Network connection mode: If there are more than 3 instruments, the network connection mode can be used. The PC computer only needs to provide a network port to control less than 60 instruments.

♦Control system: The software system of the aging instrument adopts the classic and mature C/S mode, and the communication mode is serial port and network.

♦Management software: Based on Windows operating system, using SQL database to store test data, which greatly facilitates the staff to query and export data online. According to the battery bar code, time, and device number, you can view the charge and discharge aging curve, and you can also export the curve.

 

 

Scope of application:
12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell




 

Application areas:


12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell


Technical parameter:
Input power AC 220V ±10% 50Hz
Voltage Testing range 7-70V
Accuracy ±(0.2% of reading +0.2% of range)
Electric current Charging range 50-5000mA
Charging accuracy ±(0.2% of reading +0.2% of range)
Discharge range 50-10000mA
Accuracy ±(0.2% of reading +0.2% of range)
Charge Constant voltage cut-off current 50mA minimum
Capacity Accuracy ±1‰
Power Discharge power ≤700W
Time Inspection time Receive real time <2S
Timing range 0-999 hours/step
Data logging interval ≥5S
Number of cabinet channels 12 channels, 4 rows and 3 columns
Charge Charging mode Constant current and constant
voltage charging
Cut-off condition Voltage, current, relative time,
overcharge protection.
Cycle Cycle test range 1-999
Number of single cycle steps 100
Voltage and current
detection sampling
Four-wire sampling
Database Use SQL database to manage test data
Host computer
communication method
Based on TCP/IP protocol, serial port
Data transmission mode EXCEL,TXT,Chart
Communication interface Network port
Case size 300*450*170mm
Cabinet size 960*600*1900mm
Battery space size 900*600*130mm

 ♦Support customized single-channel voltage of 7-70V, 7.5-85V products.

12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell



Product display:
12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell



Packing:
12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell


12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell

If you want to know more, please feel free to contact:
12 Channel 70V 5A Charge and 10A Discharge Battery Pack Aging Machine for Cylindrical or Pouch Cell

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now