After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Type: | Batteries Monomer Tester |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
model | MDSC- S16-64-30 | MDSC- S15-64-30 | MDSC- S16-94-20 |
Device channel number | The whole machine has 64 channels | The whole machine has 64 channels | The whole machine has 512 channels |
Dimensions | 1895mm×900mm×1840mm | 1680mm×930mm×1840mm | 1850mm×900mm×1840mm |
Chassis color | Standard beige (customizable) | ||
Fixture form | downstroke | Terminal block + Alligator clip | downstroke |
Fixture spacing | 40-155mm | 150mm | 40-155mm |
Support battery specifications | Square, high110-220mm,thick15-75mm,wide 65-220mm | Polymer cell, square cell (with pole ear) | Square, high110-220mm,thick15-75mm wide 65-220mm |
Power supply | Three-phase five-wire system AC380V±10%, 50HZ | ||
Working power consumption | ≤16KW | ≤16KW | ≤16KW |
working environment | Temperature 0~40ºC, relative humidity≤80% | ||
Cooling method | Natural intake, upward exhaust |
model | MDSC- S16-64-30 | MDSC- S15-64-30 | MDSC- S16-94-20 |
Voltage measurement range | 0~5V | ||
Battery voltage range | Charge 0~4.5V; Discharge 4.5~2V | ||
Constant voltage range | 2.5~4.5V | ||
Voltage accuracy | ±(1‰ reading+1‰ full scale) | ||
Voltage resolution | 1mV | ||
Voltage stability | ≤1‰ | ||
Current range | Charge 200mA~20A Discharge200mA~20A |
Charge300mA~30A Discharge 300mA~30A |
Charge 200mA~20A Discharge 200mA~20A |
Current accuracy | ±(1‰ reading+1‰ full scale) | ||
Current resolution | 10mA | ||
Stable current | ≤1‰ |
model | MDSC- S16-64-30 | MDSC- S15-64-30 | MDSC- S16-94-20 |
way to control | The software is installed on the computer to connect to the equipment, and the whole cabinet is controlled | ||
communication method | Serial port, baud rate 57600 | ||
Process settings | Up to 32 steps and 256 cycles can be set | ||
Charging mode | Constant current, constant voltage, constant current and constant voltage | ||
Charging cut-off condition | Voltage, current, time, capacity | ||
Discharge mode | Constant current | ||
Discharge cut-off condition | Voltage, time, capacity | ||
Protective function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery | ||
time limit | Arbitrarily set within 0~30000 minutes, the time unit is min | ||
Time accuracy | ≤±1‰ | ||
Sampling inspection cycle | ≤3s | ||
Minimum data recording frequency | ≤5s | ||
Battery sorting | Sort by (capacity, time, open circuit voltage, discharge platform, etc.) | ||
data processing | Can record voltage, current, time, capacity and other data, automatically calculate constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data, provide data graphs and cycle diagrams; can output generated text, EXCEL, WORD Or MDB database format file |